免费咨询热线
177-5963-5229ABB AO890 3BSC690072R1 模拟输出模块
ABB AO890 3BSC690072R1 模拟输出模块
ABB AO890 3BSC690072R1 模拟输出模块
3BSC690072R1 AO890 ABB冗余应用模拟输出模块
欢迎选择深圳长欣
3HAC024322-001 ABB
DSTX170 57160001-ADK ABB
DSQC625 3HAC020464-001 ABB
3ADT309600R1012 ABB
DSQC378B 3HNE00421-1 ABB
3ADT313900R1501 SDCS-CON-4 ABB
3ADT315100R1001 SDCS-POW-4 ABB
AI835A 3BSE051306R1 ABB
关于我们:
质量方针:质量保证,信誉至上
公司始终秉承“诚信、高效、共赢、创新”的经营理念,以“诚信服务、客户至上”的态度服务每一位新老客户。公司凭借极具竞争力的产品价格、庞大的库存、优良的品质、快捷的交货期、售前咨询和售后服务,不断为广大客户提供更多更好的产品
主营产品,备件供应,充足库存
Foxboro(福克斯波罗):I/A Series系统,FBM全系列(现场输入/输出模块)
顺序控制、梯形逻辑控制、事故追忆处理、数模转换、输入/输出信号处理、
数据通信及处理等。
Westinghouse(西屋):1C31系列DCS系统、CPU、OVATION系统、WDPF系统、
WEStation系统备件。
Triconex(英维思):冗余容错控制系统、基于三重模件冗余(TMR)结构的现代化的容错控制器。
EMERSON(艾默生):模块、卡件、驱动器等各类备件。
2. Common fault handling of IPC in broadcast transmitter
2.1 COM port communication is not normal
Fault phenomenon: when communicating with other COM port equipment RS-485, it can not be sent or received, or it can not be sent, etc.
Fault analysis: Usually, when programming COM communication, it is necessary to judge the communication state of COM port in advance. Make sure that you can send data when it's valid and receive data when it's valid. This is called RTS communication. However, in order to facilitate programming and speed up program execution, some users did not confirm the COM port communication state before designing the hardware, and did not pay attention to the query transceiver state during programming, which is also called AUTO communication mode. Considering its versatility, usually the motherboard with COM port is RTS communication, so when used for RS-485 communication, there will be a can send can not receive or can not receive the fault phenomenon;
Solution: The simplest solution to this problem is to use the EVOC product Ark-14520 (RS232 to RS485 module). However, if it is the communication between the COM port on the motherboard, usually there will be no such problem.
2.2 LCD display is not bright
Fault phenomenon: when the case on power, LCD display without any response;
Failure analysis: the direct cause of this failure is that the LCD backlight is not lit. After the maintenance personnel used a multimeter to measure the input power supply voltage of the backlight drive panel inverter, they found that +12V was not input. When the input power supply of the backlight drive panel was cut off, the voltage was normal. It is judged that the fault is caused by short circuit of +12V power supply on the backlight drive plate.
Solution: remove the backlight drive plate with short circuit problem from the chassis, and then power it on, so that the problem can be effectively solved. If necessary, some protective measures should be taken for the backlight drive panel to avoid such problems again.